AXITEC GmbH
Address:
Otto-Lilienthal-Str. 5, 71034 Böblingen, Germany
Website:
www.axitecsolar.com
Phone:
+49 7031 62885186
Fax:
+49 7031 62885187
E-mail:
info
axitecsolar.com
Number of Staff
15
Crystalline
Monocrystalline, Polycrystalline
MWp Sold/2011
--
Power Range
230-250
Innovative Panel Design
Other
MWp Sold/2011
--
Power Range
--
Parent Company
--
Products
Monocrystalline
Polycrystalline
AC-240P/156-60S
AC-245M/156-60S
AC-245M/156-60S IN
Model No.
AC-240P/156-60S
Click to enlarge
Panel Power Range
240-250/5 W
Electrical Characteristics for STC
Maximum Power (Pmax)
240 W
Voltage at Maximum Power (Vmpp)
30.65 V
Current at Maximum Power (Impp)
7.96 A
Open Circuit Voltage (Voc)
36.90 V
Short Circuit Current (Isc)
8.63 A
Module Efficiency
14.48 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
45 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.42 %/K
Temperature coefficient of Voc
-0.34 %/K
Temperature coefficient of Isc
0.04 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
16 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1663x997x38 mm
Weight
22 kg
Cell Size
156x156 mm
Cell Number
60
Front Cover
4 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
38 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
H+S, IP68, twist-on
Cable
4 mm² x 1000 mm length Radox cable
Certifications
TÜV Rheinland
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Model No.
AC-245M/156-60S
Click to enlarge
Panel Power Range
245-255/5 W
Electrical Characteristics for STC
Maximum Power (Pmax)
245 W
Voltage at Maximum Power (Vmpp)
29.23 V
Current at Maximum Power (Impp)
8.40 A
Open Circuit Voltage (Voc)
37.73 V
Short Circuit Current (Isc)
8.72 A
Module Efficiency
15.06 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
45 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.40 %/K
Temperature coefficient of Voc
-0.32 %/K
Temperature coefficient of Isc
0.04 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
30 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1640x992x40 mm
Weight
20 kg
Cell Size
156x156 mm
Cell Number
60
Front Cover
3.2 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
40 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
Plug/socket IP67, MC4
Cable
4 mm² x 1100 mm length
Certifications
TÜV Rheinland
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Model No.
AC-245M/156-60S IN
Click to enlarge
Panel Power Range
245-250/5 W
Electrical Characteristics for STC
Maximum Power (Pmax)
245 W
Voltage at Maximum Power (Vmpp)
29.23 V
Current at Maximum Power (Impp)
8.40 A
Open Circuit Voltage (Voc)
37.73 V
Short Circuit Current (Isc)
8.72 A
Module Efficiency
15.22 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
45 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.40 %/K
Temperature coefficient of Voc
-0.32 %/K
Temperature coefficient of Isc
0.04 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
30 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1684x1017x35 mm
Weight
19.5 kg
Cell Size
156x156 mm
Cell Number
60
Front Cover
3.2 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
17 mm Black Anodised aluminium Frame
Junction Box
IP65
Connector
Plug/socket IP67, MC4
Cable
4 mm² x 1100 mm length
Certifications
TÜV Rheinland
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
AC-206P/156-54S
AC-224P/156-60S
AC-210P/156-54S
AC-225P/156-60S
Model No.
AC-206P/156-54S
Click to enlarge
Panel Power Range
206-218/4 W
Electrical Characteristics for STC
Maximum Power (Pmax)
206 W
Voltage at Maximum Power (Vmpp)
26.39 V
Current at Maximum Power (Impp)
7.82 A
Open Circuit Voltage (Voc)
32.99 V
Short Circuit Current (Isc)
8.36 A
Module Efficiency
14.03 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
48 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.43 %/K
Temperature coefficient of Voc
-0.34 %/K
Temperature coefficient of Isc
0.05 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
16 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1501x990x38 mm
Weight
20 kg
Cell Size
156x156 mm
Cell Number
54
Front Cover
4 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
38 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
H+S, IP68, twist-on
Cable
4 mm² x 1000 mm length Radox cable
Certifications
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Model No.
AC-224P/156-60S
Click to enlarge
Panel Power Range
224-242/6 W
Electrical Characteristics for STC
Maximum Power (Pmax)
242 W
Voltage at Maximum Power (Vmpp)
29.97 V
Current at Maximum Power (Impp)
8.08 A
Open Circuit Voltage (Voc)
36.85 V
Short Circuit Current (Isc)
8.53 A
Module Efficiency
14.60 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
45 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.43 %/K
Temperature coefficient of Voc
-0.34 %/K
Temperature coefficient of Isc
0.05 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
16 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1663x997x38 mm
Weight
22 kg
Cell Size
156x156 mm
Cell Number
60
Front Cover
4 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
38 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
H+S, IP68, twist-on
Cable
4 mm² x 1000 mm length Radox cable
Certifications
TÜV Rheinland
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Model No.
AC-210P/156-54S
Click to enlarge
Panel Power Range
210-218/4 W
Electrical Characteristics for STC
Maximum Power (Pmax)
210 W
Voltage at Maximum Power (Vmpp)
26.80 V
Current at Maximum Power (Impp)
7.85 A
Open Circuit Voltage (Voc)
33.65 V
Short Circuit Current (Isc)
8.39 A
Module Efficiency
13.38 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
48 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.43 %/K
Temperature coefficient of Voc
-0.34 %/K
Temperature coefficient of Isc
0.05 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
16 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1545x1016x35 mm
Weight
19.4 kg
Cell Size
156x156 mm
Cell Number
54
Front Cover
4 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
38 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
H+S, IP68, twist-on
Cable
4 mm² x 1000 mm length Radox cable
Certifications
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Model No.
AC-225P/156-60S
Click to enlarge
Panel Power Range
225-235/5 W
Electrical Characteristics for STC
Maximum Power (Pmax)
225 W
Voltage at Maximum Power (Vmpp)
29.90 V
Current at Maximum Power (Impp)
7.53 A
Open Circuit Voltage (Voc)
36.70 V
Short Circuit Current (Isc)
8.18 A
Module Efficiency
13.83 %
Power Tolerance
± 3 %
Standard Test Conditions (STC): air mass AM 1.5, irradiance 1000W/m
2
, cell temperature 25°C
Electrical Characteristics for NOCT
Temperature
45 ± 2 °C
Nominal Operating Cell Temperature (NOCT): 800W/m
2
, AM 1.5, windspeed 1m/s,ambient temperature 20°C
Thermal Characteristics
Temperature coefficient of Pmax
-0.46 %/K
Temperature coefficient of Voc
-0.33 %/K
Temperature coefficient of Isc
0.06 %/K
System Integration Parameters
Maximum System Voltage
1000 V
Series Fuse Rating
30 A
No. of Bypass Diodes
3
Mechanical Characteristics
Module Dimension
1640x992x40 mm
Weight
20 kg
Cell Size
156x156 mm
Cell Number
60
Front Cover
3.2 mm hardened, low reflection white glass
Back Cover
Composite Film
Frame Type
40 mm Silver Anodised aluminium Frame
Junction Box
IP65
Connector
Plug/socket IP67, MC4
Cable
4 mm² x 1100 mm length
Certifications
TÜV Rheinland
TÜV SUD
PV Cycle
Safety Class II
IEC
Download Manufacturer's PDF
Sellers
France
Krannich Solar
Germany
Bauer Solarstrom
,
Elektro-Rückert
,
Elektro Engelhardt
,
Elektro Loresch
,
Genzwürker Elektrotechnik
,
Hilz Elektrotechnik
,
JSV-OHG Photovoltaik
,
Krannich Solar
,
Loma-Solar
,
SunEffects
Greece
Krannich Solar
Italy
Krannich Solar
S. Korea
Krannich Solar
Spain
Krannich Solar
Switzerland
FankhauserSolar
USA
Krannich Solar
Last Update
24-05-2012
Banner Advertising on ENF
Sponsored Links on Database Lists
Additional Information for Company Profiles
© 2005-2012
ENF Ltd.
All Rights Reserved